Accidents in tunnels often result in tragic consequences, particularly if the incident is fire related. Heat, smoke, and toxic gases can quickly cause chaos and panic, making it challenging for tunnel users to evacuate safely. Everlux AL addresses this issue by providing consistent, continuous safety information detailing the egress pathway, emergency exits, fire safety equipment, emergency telephones, and places of refuge.
Everlux AL signs are manufactured on a durable 2mm thick aluminum base to ensure high performance in extreme conditions. Each Everlux AL sign features a transparent protective film that offers protection against graffiti and, more importantly, resistance to tunnel atmospheric conditions such as humidity and moisture as well as silt, salt and smog.
Everlux AL safety signs comply with the NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways. This standard provides fire protection and fire life safety requirements for limited access highways, road tunnels, bridges, elevated highways, depressed highways, and roadways beneath air-right structures.
The NFPA 502 standard requires directional signs indicating the distance to the two nearest emergency exits on the side walls of road tunnels at intervals no more than 82 feet. Everlux AL signage meets this requirement, making it an ideal solution for improving safety in road tunnels.
Everlux AL demonstrates Everlux’s commitment to improving safety in confined environments. Everlux AL ensures that tunnel users have access to vital safety information, helping them evacuate safely and independently in the event of an incident, thereby contributing to a safer environment within these structures.
For more information or to discuss how Everlux can help you design and specify your tunnel egress signage solution, please contact us!
As global urbanization accelerates, the need for effective fire safety measures in residential buildings, particularly in high-rise residential buildings, is more critical than ever.
In New York City, fire safety regulations for residential buildings include specific requirements for apartment and guest room identification and directional markings and signs, as outlined in 3 RCNY §505-01. Additionally, entrance door fire emergency markings in apartments, guest rooms, sleeping rooms, and stairwell doors are mandated under 3 RCNY §505-02. These rules apply to Group R-1 and R-2 buildings.
Stipulates the requirements for the design and placement of entrance door room number markings for dwelling units in all Group R-1 and Group R-2 buildings and occupancies, and lobby and hallway corridor directional signs.
The signs and markings required under this section are meant to assist emergency response personnel in locating the dwelling units they need to respond to.
It mandates that all entrance doors to dwelling units and stairwells doors in Group-1 and Group-2 buildings or occupancies have specific markings to aid firefighters in locating such dwelling units, stairwells, and in identifying multi-floor dwelling units.
These markings should be affixed to the door jamb on the hinged side of the door, not more than 12 inches above the floor. For multi-floor dwelling units, additional markings with directional arrows are required.
Everlux offers a bespoke signage solution that meet the stringent requirements of the New York City Fire Department rules 3 RCNY §505-01 and 3 RCNY §505-02 ensuring that each sign is uniquely tailored to the building’s specific needs.
In conclusion, Everlux is dedicated to improving fire safety in high-rise residential buildings. With its assortment of compliant, customizable, and high-visibility signage, Everlux is at the forefront of ensuring safety is not just a regulation, but a guarantee.
For more information about Everlux products and 3 RCNY §505-01 and 3 RCNY §505-02 Signs and Markings, contact us.